24/7 Emergency BMS & HVAC SupportCall Now: 07427 826446
Packaged Gasketed Plate Heat Exchanger — BMS control panel, plantroom & head-end reference photo
Vendor-Independent BMS Specialists

Packaged Gasketed Plate Heat Exchanger

Skid-mounted gasketed plate heat exchanger packages for hydraulic separation, district heating interfaces and DHW generation — 50 kW to 5 MW.

Response SLA
4hr

Critical-site response nationwide.

Accredited & Insured
Trusted by FM teams

£10M PL insurance.

Platforms
TrendTridiumSiemensSchneiderHoneywell
BS EN 61439 verified panels
BACnet · Modbus · KNX
500+ sites under PPM
All services
Packaged gasketed plate heat exchanger on a galvanised skid with stainless steel plate pack, insulated pipework, isolation valves, pressure gauges and pre-wired control panel

Commercial Heating

Packaged Gasketed Plate Heat Exchanger

Skid-mounted gasketed plate heat exchanger packages for hydraulic separation, district heating interfaces and DHW generation — 50 kW to 5 MW.

Key features

  • Gasketed plate heat exchanger duties from 50 kW to 5 MW
  • 316 stainless steel plates with EPDM or NBR gaskets
  • Pre-piped primary and secondary pumps, valves and strainers
  • Temperature, pressure and flow sensors wired to BMS-ready panel
  • Factory pressure-tested and thermally commissioned before despatch

About this product

Our packaged gasketed plate heat exchanger units provide hydraulic separation between primary and secondary circuits in commercial heating, district heating and domestic hot water systems. The gasketed plate construction allows the unit to be opened, cleaned and re-plated on site as duties change — a major lifecycle advantage over brazed alternatives in hard-water or fouling environments.

Each package is built around a 316 stainless steel plate pack with EPDM (heating) or NBR (DHW) gaskets, sized for the specified duty, approach temperature and allowable pressure drop. Primary and secondary pumps, two-port control valves, isolation valves, strainers, pressure relief, expansion connections and full instrumentation are pre-piped onto a galvanised skid and lagged ready for installation.

A pre-wired BMS-ready control panel manages secondary flow temperature against a compensated set-point, sequences pumps with duty rotation and reports alarms via volt-free contacts or BACnet/Modbus. Every unit ships with a witness-tested commissioning certificate, plate selection sheet and full O&M documentation — ideal for district heating HIU rooms, landlord plant rooms and DHW generation skids.

What a packaged plate heat exchanger includes

Each package is built around a gasketed plate heat exchanger with a 316 stainless steel plate pack, selected for the duty, approach temperature and allowable pressure drop. Around it we pre-pipe the primary and secondary pumps, two-port control valves, isolation valves, strainers, pressure relief and expansion connections, then lag the pipework on a galvanised skid.

Temperature, pressure and flow sensors are wired back to a BMS-ready control panel. The panel holds secondary flow temperature against a compensated set-point, rotates duty and standby pumps, and reports alarms by volt-free contacts or over BACnet or Modbus, so the unit can be monitored from your existing head-end.

Common uses and when to choose a gasketed unit

Typical applications are district heating interface rooms, landlord plant rooms that separate a central primary circuit from individual secondary circuits, and domestic hot water generation. Gaskets are EPDM for heating duties and NBR for DHW duties.

A gasketed plate heat exchanger can be opened, cleaned and re-plated on site. That makes it a strong choice in hard-water or fouling conditions, or where the duty is likely to change over the life of the building — a brazed unit cannot be opened and normally has to be replaced when it fouls or the load grows.

Frequently asked questions

What is a packaged gasketed plate heat exchanger?

It is a skid-mounted unit combining a gasketed plate heat exchanger with pumps, valves, strainers, sensors and a pre-wired control panel, giving hydraulic separation between a primary and secondary circuit.

What duties are available?

Packaged gasketed plate heat exchanger units are available for duties from 50 kW to 5 MW.

Why choose gasketed over brazed plates?

Gasketed units can be opened, cleaned and re-plated on site as duties change, which is a lifecycle advantage in hard-water or fouling environments where brazed units would need replacing.

Which gaskets are used?

Plates are 316 stainless steel, with EPDM gaskets for heating duties and NBR gaskets for domestic hot water duties.

Can the unit report to our BMS?

Yes. The control panel reports alarms by volt-free contacts or BACnet/Modbus, and controls secondary flow temperature and pump duty rotation.

Related pages

Ape-Strong Multi-Vendor Controls Specialists

Trend · Tridium Niagara · Siemens · Schneider Electric · Honeywell — BACnet, Modbus & KNX integration.

Ape BMS Controls logoApe BMS Controls

Contact

Ape BMS Controls

07427 826446 Book online

London, the Home Counties & nationwide projects

  • Find us on: