24/7 Emergency BMS & HVAC SupportCall Now: 07427 826446
PLC Programming — BMS control panel, plantroom & head-end reference photo
PLC Programming Specialists

PLC Programming

Independent PLC software engineering — IEC 61131-3 ladder, structured text and function block, written to a documented standard, peer-reviewed and committed to Git-backed version control.

Response SLA
4hr

Critical-site response nationwide.

Accredited & Insured
Trusted by FM teams

£10M PL insurance.

Platforms
TrendTridiumSiemensSchneiderHoneywell
Vendor-independent across every major controls platform
Witnessed FAT/SAT and full O&M handover pack
Engineers covering every region
4-hour critical SLA for contract clients
BS EN 61439 verified panels
BACnet · Modbus · KNX
500+ sites under PPM

What We Deliver

Multi-Vendor PLC

Siemens (TIA Portal, Step 7, Climatix), Allen-Bradley (Studio 5000, RSLogix 500/5000), Mitsubishi (GX Works), ABB AC500 and Schneider EcoStruxure Control Expert.

All IEC 61131-3 Languages

Ladder Diagram, Structured Text, Function Block Diagram, Sequential Function Chart and Instruction List — written to our in-house coding standard.

Safety PLC Programming

Siemens Safety Advanced (F-CPU), Rockwell GuardLogix, Pilz PNOZmulti and Sick Flexi Soft — designed and validated to BS EN ISO 13849 / IEC 62061.

HMI & SCADA Programming

Siemens WinCC and Comfort Panels, Rockwell FactoryTalk View, Mitsubishi GOT, ABB Panel Builder, Ignition, AVEVA / Wonderware and Citect.

Version Control & Code Review

Git-backed (TIA Portal Multiuser, FactoryTalk AssetCentre or external Git), peer code review against a documented standard, witnessed FAT before site mobilisation.

Legacy Migration

Reverse-engineer and re-platform legacy Siemens S5/S7, Allen-Bradley PLC-5 / SLC-500 and Mitsubishi FX programs to fully documented, maintainable code.

Platforms & Brands We Support

Our engineers are vendor-trained across the platforms below — so a single contract covers your entire estate, with no lock-in.

Siemens TIA PortalSiemens Step 7Siemens ClimatixAllen-Bradley Studio 5000Allen-Bradley RSLogix 500/5000Mitsubishi GX Works2/3ABB AC500ABB Automation BuilderSchneider EcoStruxurePilz PNOZmultiSiemens Safety F-CPURockwell GuardLogix

PLC Programming, Done to a Documented Standard

Most undocumented PLC code was written in good faith twenty years ago by an engineer who has long since retired. The plant runs — but no one alive can confidently change it. Our PLC programming service exists to solve exactly that problem: write maintainable, peer-reviewed, version-controlled code today, so the next engineer in (whether ours or yours) can pick it up in minutes rather than days.

Every project follows the same workflow: capture intent in a signed-off Functional Design Specification, develop against our in-house IEC 61131-3 coding standard, peer code-review every commit, run a witnessed Factory Acceptance Test, then commission and Site Acceptance Test on the live plant.

Vendor Coverage and Languages

We program every major PLC platform in the market: Siemens (TIA Portal, Step 7, Climatix BMS controllers), Allen-Bradley (Studio 5000 for CompactLogix and ControlLogix, RSLogix 500 for SLC-500 and MicroLogix), Mitsubishi (GX Works2 / GX Works3 for FX, Q-Series and iQ-R), ABB (AC500 in Automation Builder) and Schneider (EcoStruxure Control Expert for Modicon).

All five IEC 61131-3 languages are in active use depending on the task: Ladder Diagram for discrete logic and machine interlocks; Structured Text for maths, recipe handling and looping operations; Function Block Diagram for reusable libraries; Sequential Function Chart for batch and state-machine logic; Instruction List where legacy code requires it. We default to Ladder + Structured Text + FBD for new projects, with SFC reserved for true sequential processes.

Safety PLC and Functional Safety

Safety functions are designed and validated to BS EN ISO 13849-1 or IEC 62061 as appropriate, with safety-rated PLCs — Siemens Safety Advanced (F-CPU), Rockwell GuardLogix, Pilz PNOZmulti or Sick Flexi Soft — depending on the host platform. Each safety function carries a documented Safety Functional Requirement Specification (SFRS), a SISTEMA or PAScal calculation evidencing the required Performance Level or SIL, and a signed safety validation report at handover.

We also handle the wider machinery safety package — risk assessment, safe operating procedures, lock-off / tag-out documentation and operator training — so the client EHS team has everything they need for HSE inspection.

HMI, SCADA and Networking

PLC programming rarely lives in isolation. Every project includes the HMI / SCADA layer developed against the same tag list as the PLC — Siemens WinCC and Comfort Panels, Rockwell FactoryTalk View Studio (ME / SE), Mitsubishi GOT, ABB Panel Builder, Ignition, AVEVA / Wonderware InTouch and Citect. Graphics follow High-Performance HMI principles (ISA-101) — neutral palette, alarm-by-exception and operator-task-focused layouts.

Industrial networking is engineered as part of the same scope: Profinet, EtherNet/IP, Modbus TCP, Profibus and OPC UA, with managed industrial Ethernet (Stratix, Scalance, Hirschmann) and segmented OT VLANs. Where remote support is required after handover, we configure secure site-to-site VPN with MFA and audited session logging.

Version Control, FAT, SAT and Aftercare

Every PLC and HMI program lives in a Git-backed repository — TIA Portal Multiuser server for Siemens, FactoryTalk AssetCentre for Rockwell, external Git for cross-platform projects. Every change is committed with a meaningful message, peer code-reviewed against our coding standard and tagged at each release. The client receives a complete copy of the repository at handover, plus signed-off versioned PDFs of the program for offline reference.

Witnessed FAT against the original FDS is run before any site mobilisation. On site, loop checks and point-to-point commissioning precede a witnessed SAT, after which the program is locked, the O&M pack is issued and operator and maintenance training is delivered. PPM contracts after handover include 4-hour critical SLA, remote diagnostics and an annual code review against the latest version of our standard.

FAQs about PLC Programming

Which PLC platforms do you program?+

Siemens (TIA Portal, Step 7, Climatix), Allen-Bradley (Studio 5000, RSLogix 500/5000, MicroLogix, CompactLogix, ControlLogix), Mitsubishi (GX Works2/3 — FX, Q-Series, iQ-R), ABB (AC500, Automation Builder) and Schneider (EcoStruxure Control Expert / Modicon).

Which IEC 61131-3 languages do you write in?+

All five — Ladder Diagram (LD), Structured Text (ST), Function Block Diagram (FBD), Sequential Function Chart (SFC) and Instruction List (IL). New projects default to LD + ST + FBD, with SFC reserved for true sequential processes.

Can you reverse-engineer an undocumented legacy PLC program?+

Yes — we routinely take ownership of legacy Siemens S5 / S7, Allen-Bradley PLC-5 / SLC-500 and Mitsubishi FX programs. We upload, document the logic, then optionally re-platform to a modern controller with a fully maintainable code base.

Do you handle safety PLC programming?+

Yes — Siemens Safety Advanced (F-CPU), Rockwell GuardLogix, Pilz PNOZmulti and Sick Flexi Soft, designed and validated to BS EN ISO 13849 / IEC 62061 with a signed safety validation report on completion.

How do you manage version control and code review?+

Git-backed version control (TIA Portal Multiuser, Studio 5000 with FactoryTalk AssetCentre, or external Git), mandatory peer code review against our in-house coding standard, and witnessed FAT/SAT before sign-off.

What's a typical PLC programming day rate?+

From £950 + VAT per day for senior PLC engineering, including remote development time. Site visits are charged at the same rate plus expenses; PPM contract clients receive a discounted day rate.

Free site survey for PLC Programming

Walk-through, fixed written proposal, no obligation. Engineers available across every region.

Related Automation Services

Why Engineering Teams Choose Us

Directly-employed engineers — no subcontractors
Vendor-independent — no manufacturer commission distorting recommendations
Witnessed FAT and SAT against a signed Functional Design Spec
Git-backed version control on every PLC and HMI program
Full O&M handover pack — software backups, drawings, points list
4-hour critical and next-business-day standard SLA on contracts

Ready to talk about your PLC Programming?

Speak to a BMS engineer about your estate. We provide free site surveys, no-obligation proposals and lifecycle support across every major controls platform.

Vendor-independent · Trend · Tridium · Siemens · Schneider · Honeywell

Ape-Strong Multi-Vendor Controls Specialists

Trend · Tridium Niagara · Siemens · Schneider Electric · Honeywell — BACnet, Modbus & KNX integration.

Ape BMS Controls logoApe BMS Controls

Contact

Ape BMS Controls

07427 826446 Book online

London, the Home Counties & nationwide projects

  • Find us on:

© 2026 Ape BMS Controls. All rights reserved.